Merging Pyramix 4.3 Instrukcja Użytkownika Strona 118

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 117
User Manual : Mixer Settings
User Manual
118
DSD Peak Filter
For DSD projects this drop-down list offers the choice between two filtering options which will be applied
to the DSD signal before it is measured by the level meter.
This will help enable you to ensure that the DSD signal is compatible with the AES recommendations
concerning the high frequency dither noise content.
20k
Applies a 20 kHz low pass filter to the signal, thus only the audible audio content is measured.
40k-100k
Applies a band pass filter with a frequency range of 40 kHz to 100kHz to the signal. According to the
AES recommendation the signal level in this frequency range should not exceed -20 dB.